Particle analysis in metal samples

Particle analysis in metal samples

Petition / Problem

The client wanted to find the reason why a series of surface defects of the metal parts appear in the different painting and washing stages.

Objective

Understand why this phenomenon occurs and find its cause through chemical and physical analysis.

ATRIA solution

The defect samples were observed to have Na and Cl. The presence of Na and Cl together may mean handling of the samples without gloves or salts from the water. Ca from CaCO3, (CaO + CO2) from lime in the water was also observed in all samples.